What PSI is right for a sprinkler blowout?

Quick answer

For most homes, use about 50 psi at the regulator: poly pipe 40–50 psi (max 50), PVC 50–60 psi (max 80), and drip lines 20–30 psi. Read the long, thin end of the needle; 1 bar ≈ 14.5 psi. More pressure does not clear more water and can damage pipes and heads.

By Ardeshir Adiban, HigreenWall technician

Which pressure gauge matters for a sprinkler blowout?

Outer black numbers are bar; inner red numbers are psi. 1 bar ≈ 14.5 psi, so 4 bar ≈ 58 psi. For this guide, use the inner psi scale.

These are general ranges, not a guarantee for every system. Follow the lowest pressure limit specified for your pipes, heads, valves and backflow device. If the pipe type is unknown, don't assume PVC limits apply.

Book my fall closing
Compressor gauge: outer black bar scale and inner red psi scale05101516050100150200230psibarHigreenWall
55 psi ≈ 3.8 bar
0 psi150 psi

OK for PVC (white rigid pipe), max 80

How do I read a compressor pressure gauge?

  1. 1

    Two scales. One pressure.

    Outer black numbers are bar; inner red numbers are psi. 1 bar ≈ 14.5 psi, so 4 bar ≈ 58 psi. For this guide, use the inner psi scale.

    Compressor gauge: outer black bar scale and inner red psi scale05101516050100150200230psibarHigreenWall

    4 bar ≈ 58 psi

  2. 2

    Follow the long, thin end.

    Read the long pointer, not the short, thick end. That short end is a counterweight. It may point near 200 while the actual reading is about 55 psi — it isn't a second reading.

    Compressor gauge: outer black bar scale and inner red psi scale05101516050100150200230psibarHigreenWall
    Wrong end
    Compressor gauge: outer black bar scale and inner red psi scale05101516050100150200230psibarHigreenWall
    Right end

    55 psi ≈ 3.8 bar

  3. 3

    Tank pressure isn't outlet pressure.

    The tank gauge shows stored air. A compressor normally fills to about 120–150 psi before shutting off. The regulator gauge shows what goes into your pipes — that's the number that matters.

    135 psi50 psiTankOutlet / regulatorStored airTo your pipes

    Set the regulator, not the tank pressure.

What PSI should I use to blow out sprinklers?

Sprinkler blowout pressure ranges and limits
Pipe / equipmentWorking pressureMaximumNotes
Poly pipe40–50 psi50 psiBlack, flexible pipe · never above 50 psi
PVC pipe50–60 psi80 psiWhite, rigid pipe · maximum 80 psi
Drip lines20–30 psi—Low-pressure tubing · 20–30 psi
Compressor tank120–150 psi—Let it fill completely before starting so outlet pressure stays steady.

For homeowners in Toronto and the GTA, plan your fall closing before the first hard freeze.

What happens if you use too much air pressure?

Air volume (CFM — cubic feet per minute) moves the water out, not high pressure. Too much pressure after the water is gone can create friction heat that melts or cracks fittings, damages sprinkler heads and valve diaphragms, and harms the backflow preventer.

If airflow isn't enough, don't raise the pressure. Run each zone in short bursts and let the tank recover. The compressor needs enough air volume for the system, not just a high number on its gauge.

How do technicians safely blow out sprinklers?

  • Turn off the water supply first.
  • Keep at least one zone open — never pressurize a closed system.
  • Start at 40 psi for sprinkler zones; increase only if heads don't pop up, within the component limits. Drip zones need just 20–30 psi.
  • Use short bursts per zone; let the tank recover between bursts.
  • Stop when the heads spray only a fine mist — don't keep running dry air.
  • Release the air and leave valves in the correct position for the equipment at the end.

Don't blow compressed air through a backflow preventer. Use the appropriate downstream connection and follow the device manufacturer's winterization instructions. Wear eye protection and stay clear of heads under pressure.

Doing it wrong can mean expensive repairs in spring — this is why most homeowners let a pro do it.